FHW Ag

Cat.No.:

VD128Q

Name:

Feline Heartworm Ag Test

Target:

Dirofilaria immitis antigen

Specs:

10 tests/box

Storage:

2-30 °C

Stability:

24 Months

Share to

FHW Ag
FHW Ag

Product Overview

The Feline Heartworm Ag Test is a lateral flow immunochromatographic assay designed for the detection of Dirofilaria immitis (heartworm) antigen in feline serum, plasma or whole blood, delivering a fast and visible result within 5–10 minutes.

Suitable for:

🐈 Cats at risk of infection 🏥 Veterinary clinics & animal hospitals 🐾 Rescue centers & shelters 🔬 Field screening

Key Features

🎯 Dual reading modesVisual judgment, or analysis with VETSEE G2 Dry Immunoassay Analyzer
🧬 TargetDirofilaria immitis antigen
⚡ Fast result5–10 minutes
🔬 Highly selectiveTarget-specific capture and gold-labeled detector antibodies
❄️ Room-temp storage2–30 °C, no cold chain needed
📦 Flexible packs10T kit available

Detection Principle

The test card features a testing window with an initially invisible T (test) zone and a C (control) zone. Highly selective antibodies to Dirofilaria immitis antigen serve as the capture (T) and gold-labeled detector antibodies. When the treated sample is added to the sample well, the liquid flows laterally across the test strip. If the target is present, a visible T line appears, which can also be recognized by the VETSEE G2 analyzer. The C line must always appear after sample application, indicating proper test performance.

Test Procedure

1Equilibrate — allow all components to equilibrate to room temperature (15–25 °C) for 10 minutes before use.
2Collect sample — collect serum, plasma or whole blood following standard veterinary procedures.
3Apply sample — remove the test card from the foil pouch, place it flat, and transfer 1 drop of the sample (using a capillary dropper) into the sample well.
4Add buffer — transfer 3 drops of the assay buffer (using a disposable dropper) into the sample well.
5Read result — start the timer and read at 5–10 minutes. Do not move the test card during testing.

* Instrumental method (Standard Test / Quick Test) also available with the VETSEE G2 Dry Immunoassay Analyzer — see the IFU for details.

Result Interpretation

C lineT lineResultInterpretation
VisibleVisiblePositive (+)Target detected. Any faintly visible T line is considered positive when the C line is present.
VisibleNot visibleNegative (−)No target detected.
No lineAnyInvalidTest failed; repeat with a new test card.

Results can be read visually or semi-quantitatively with the analyzer, which classifies them into five phases: negative, suspicious (grey zone), weak positive, positive and strong positive. A suspicious result is indeterminate and repeat testing is recommended. Any faintly visible T line should be considered positive when the C line is also present, and the test should be repeated if the analyzer result conflicts with the visual judgment.

* The C and T lines appear as magenta-colored lines. For in vitro veterinary use only — results should be considered alongside other clinical information.

Specifications

Cat. No.VD128Q
TargetDirofilaria immitis antigen
SpecimenFeline serum, plasma or whole blood
FormatLateral flow test card
Reading time5–10 minutes
Kit contents (10T)10 FHW Ag test cards, 10 vials of assay buffer, 10 disposable droppers, 10 capillary droppers, 1 instruction for use
Pack size10 tests / box
Storage2–30 °C
Shelf life24 months

Storage & Stability

Store the test kit at 2–30 °C in a dry place, away from direct sunlight and humidity. Do not freeze. The kit is stable for 24 months from the date of manufacture when stored under recommended conditions.

FAQ

QWhich specimens can be tested?
AFeline serum, plasma or whole blood.
QHow long until the result?
A5–10 minutes after adding the sample.
QDo I need an instrument?
ANo instrument is required for Method 1 (visual interpretation). The VETSEE G2 analyzer is optional for semi-quantitative reading.
QWhat if the T line is very faint?
AAny faintly visible T line is considered positive when the C line is present.
QCan the test card be reused?
ANo. Each card is for single use only.
QWhat does the C line mean?
AThe C (control) line must always appear after sample application, indicating proper test performance. No C line = invalid test, repeat.

Ordering Information

Cat. No.ProductPack size
VD128QFeline Heartworm Ag Test10 tests / box

Inquire Now

We will contact you within one working day. Please pay attention to your email.

REQUEST QUOTE

We will consistently provide you with high-quality products, honest service style, and reasonable product prices. If you have any questions, please feel free to leave a message for consultation!

Submit

*Note: Please make sure to fill in the information accurately and maintain smooth communication. We will contact you as soon as possible