Cf Ag

Cat.No.:

VD123Q

Name:

Feline Chlamydia Ag Test

Target:

Chlamydia felis antigen

Specs:

10 tests/box

Storage:

2-30 °C

Stability:

24 Months

Share to

Cf Ag
Cf Ag

Product Overview

The Felivet Chlamydia Ag Test is a lateral flow immunochromatographic assay for the detection of Chlamydia felis antigen (Cf Ag) in secretions from the feline eye conjunctiva. The swab specimen is processed with two assay buffers in an extraction tube, and results can be read visually or further analyzed with a dry immunoassay analyzer.

Suitable for:

🐈 Cats at risk of infection 🏥 Veterinary clinics & animal hospitals 🐾 Rescue centers & shelters 🔬 Field screening

Key Features

🎯 Dual reading modesVisual judgment, or analysis with VETSEE G2 Dry Immunoassay Analyzer
🧬 TargetChlamydia felis antigen
⚡ Fast result5–10 minutes
🔬 Highly selectiveTarget-specific capture and gold-labeled detector antibodies
❄️ Room-temp storage2–30 °C, no cold chain needed
📦 Flexible packs10T kit available

Detection Principle

The test card features a testing window with an initially invisible T (test) zone and a C (control) zone. Highly selective antibodies to chlamydia felis antigen serve as the capture (T) and gold-labeled detector antibodies. When the treated sample is added to the sample well, the liquid flows laterally across the test strip. If the target is present, a visible T line appears, which can also be recognized by the VETSEE G2 analyzer. The C line must always appear after sample application, indicating proper test performance.

Test Procedure

1Collect the specimen — Collect secretions from the feline eye conjunctiva with the swab until the swab is wet sufficiently.
2Extract with buffer A — Add 10 drops of assay buffer A (approx. 300 uL) into an extraction tube, insert the swab, agitate thoroughly and press the bottom of the tube. Wait for 2 minutes.
3Add buffer B — Add 8 drops of assay buffer B (approx. 250 uL) into the tube, agitate the swab thoroughly and press the bottom of the tube again. Wait for 1 minute.
4Prepare the sample — Press the swab against the side of the tube and squeeze the tube while pulling out the swab to retain as much liquid as possible, then attach the dropper tip to the top of the extraction tube.
5Run the test — Add 4 drops of the treated sample into the sample well of the test card and read the result within 10 minutes.

* Instrumental method (Standard Test / Quick Test) also available with the VETSEE G2 Dry Immunoassay Analyzer — see the IFU for details.

Result Interpretation

C lineT lineResultInterpretation
VisibleVisiblePositive (+)Target detected. Any faintly visible T line is considered positive when the C line is present.
VisibleNot visibleNegative (−)No target detected.
No lineAnyInvalidTest failed; repeat with a new test card.

With the analyzer, the result can be classified into five phases: negative (-), suspicious (+/-), weak positive (+), positive (++) and strong positive (+++), according to the Cf load. A suspicious (+/-) result is indeterminate and repeat testing is recommended.

* The C and T lines appear as magenta-colored lines. For in vitro veterinary use only — results should be considered alongside other clinical information.

Specifications

Cat. No.VD123Q
TargetChlamydia felis antigen
SpecimenFeline secretions from the eye conjunctiva
FormatLateral flow test card
Reading time5–10 minutes
Kit contents (10T)10 Cf Ag test cards, 1 vial of assay buffer A, 1 vial of assay buffer B, 10 extraction tubes, 10 dropper tips, 10 specimen collection swabs, 1 instruction for use
Pack size10 tests / box
Storage2–30 °C
Shelf life24 months

Storage & Stability

Store the test kit at 2–30 °C in a dry place, away from direct sunlight and humidity. Do not freeze. The kit is stable for 24 months from the date of manufacture when stored under recommended conditions.

FAQ

QWhich specimens can be tested?
AFeline secretions from the eye conjunctiva.
QHow long until the result?
A5–10 minutes after adding the sample.
QDo I need an instrument?
ANo instrument is required for Method 1 (visual interpretation). The VETSEE G2 analyzer is optional for semi-quantitative reading.
QWhat if the T line is very faint?
AAny faintly visible T line is considered positive when the C line is present.
QCan the test card be reused?
ANo. Each card is for single use only.
QWhat does the C line mean?
AThe C (control) line must always appear after sample application, indicating proper test performance. No C line = invalid test, repeat.

Ordering Information

Cat. No.ProductPack size
VD123QFelivet Chlamydia Ag Test10 tests / box

Inquire Now

We will contact you within one working day. Please pay attention to your email.

REQUEST QUOTE

We will consistently provide you with high-quality products, honest service style, and reasonable product prices. If you have any questions, please feel free to leave a message for consultation!

Submit

*Note: Please make sure to fill in the information accurately and maintain smooth communication. We will contact you as soon as possible